Workflow Status

The purpose of this page is to provide the ability to submit the current Site Visit Report by updating the workflow status.

 

 

Change Signing Password (if necessary)

First-time users to this module will need to create a signing password, if they have not done so already, by clicking , which opens the My Signing Password module. This button will be hidden if the Use Login Password for Electronic Signature Configuration variable under the Security configuration group is set to True or if the Enable Electronic Signature on Site Visit Reports configuration variable under the Site Visit Reports configuration group is set to False.

 

 

Electronic Signature

To electronically sign the report, you will enter your password, either the signing password, if required, or the login password. Then click . The system will check:

 

 

Unsuccessful Attempt

A failed counter will start if you were unsuccessful in signing the report and you will be locked out of signing if the count is greater than the value set in the Signature Password Failed Attempts Configuration Variable under the Site Visit Report configuration group. You will need to change your Signature Password. You may need to contact your administrator for assistance.

 

 

Successful Attempt

You are returned to the Overview tab. A PDF version of the Site Visit Report will be created for each workflow step updated at this time. Each workflow step will be signed, if appropriate, based on the Site Visit Report Workflow Process. A Site Visit Report Workflow History record will be created for each workflow step. The Site Visit Report Workflow Status will be advanced to the final workflow step affected by this update. Depending on the workflow step and the user’s report roles, multiple workflow steps may be completed sequentially during this update. For example, a Report Reviewer may also be a Report Approver. If the Reviewer does not have any Review Comments, then signing the report will update both the review and approve steps.

 

 

Locking Sub-Reports

When the author successfully saves the report, the report's status becomes First Draft. The sub-reports that are connected to the report are locked to prevent changes to data (such as Documents, Subjects, Consents, Deviations, Issues, SAEs, etc.) after the author signs the report and through the review and approval process. When the Reviewer returns the report to the author with comments (Comments Returned), the lock is cleared, which allows additional data to be included. The author then re-signs the report with the new data (Revisions Completed) and the data is locked again.

 

Unlocking Sub-Reports

On the History Tab, edit the Revisions Completed Workflow status, and use the Undo Status button to return the report to the Comments Returned workflow.  This will unlock the data on the report.  The Issues should then appear on the report when previewed.  Finally, the author can use the Update Workflow button again to return the status to Revisions Completed.

 

Click Common Buttons for a description of the buttons found throughout the system and their uses.

 

 

Field

Description

Report Status

This field is read only and a message will explain whether the Site Visit Report is ready to update to the next workflow status or give a reason why it is not ready, such as due to pending Panel Fields or open Review Comments.

Workflow Action

This field is read only and describes the action that needs to be taken.

Electronic Signature

This section will be hidden if the Enable Electronic Signature on Site Visit Report Configuration variable is set to False.

Attestation Statement

This field read only and will be hidden if no signature is required. The text for this field is determined by the values of the Site Visit Report Author Signature Text and the Site Visit Report Approver Signature Text in the Site Visit configuration group, depending on whether the Report Author or the Report Approver is signing.

Name

This field will be hidden if no signature is required. If required, the full name of the current user will display and be read only.

Title

This field will be hidden if no signature is required. If required, the title of the current user from their Global Contact record will display and be read only.

Signing Password (PIN)

This field will be hidden if no signature is required. If visible, it is required and can hold up to 20 characters. For security purposes, the characters for this field will be hidden from view while typing. If the Use Login Password for Electronic Signature Configuration variable under the Site Visit Report configuration group is set to True, then the caption for this field will change to Password.

Optional Comment

This field can hold up to 500 characters.